Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02300
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2007 | FRAMING | Approved | IVRS - Inspection :* | |
12/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 6" PEX TO H20 HTR FLUE 2) 10' LIMIT 3' TRAP ARM TOILET GARAGE 3) BLOCK MECH LAUNDRY, BATH 1ST FLOOR, KITCHEN 4) NAIL STUDS TOGETHER GARAGE SHEAR AT H.D.'S 5) SHIM ALL LET INS, AT LIVING ROOM, WEST WALL REMOVE LET IN SITER NEW STUDS 6) ZERO GAS PRESSURE 7) TUB, BLK 2ND FLOOR 8) WRAP LINE SET 2ND FLOOR EXPOSED ? 9) BETWEEN FLOORS CRIPPLE AT DBL STUDS ABOVE KITCHEN AND LIVING ROOM 10) LOOSE FLOOR/DECKING IN 2ND FLOOR BATH 11) FILL IN CORNER WITH BLK 2ND FLOOR ALCOVE 12) SISTER STUDS AT KITCHEN LET INS OVER NOTCHED 13) GAS LINE AT FLOOR GUSSET LIVING ROOM 14) MARKED ON FLOOR MISSING BOLTS A SHEARWALLS |