Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FINISH RE-NAILING HANGER S/E GIRDER 2ND FLOOR 2) REAR SHEAR BLK AT BOTTOM, AND RENAIL BOTTOM OF SHEET 2ND FLOOR ( SEE SHINNERS( 3) REPLACE CRACKED STUD AT STRONG BACK, WEST REAR 4) CHECK AT NEXT INSPECTION |
|
| 10/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WHAT SIZE NAILS ARE IN HANGERS AT GIRDER TRUSSES 2) MISSING TRUSS HANGERS FRONT PORCH, HIP JOINTS ROOF 3) REAR SHEAR 2ND FLOOR CLIP END OF SHEAR WALL TO TRUSS CHORD 4) NAIL ALL 2ND FLOOR SHEARWALLS BOTTOM PLATES 12" ON CENTER 16DS, NAIL OFF ALL OTHER PLATES 5) REPLACE ALL OVER NOTCHED LET IN STUDS, JOINTS TO BE TIGHT |