Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02294
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2007 | FRAMING | Approved | IVRS - Inspection :* | |
01/22/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) RETRO H.D. MASTER BATH OK 2) STUCCO MESH NORTH GABLE END |
|
01/16/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO REMOVE SHOWER ENCLOSURE TO CHECK FOR RETRO, METAL CLIP WAS NEVER SIGNED BECAUSE IT NEEDS TO BE INSULATED 2) LATHE NOT COMPLETE 3) NO WATER IN SYSTEM TO CHECK DWV |
|
01/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATHE NOT COMPLETE 2) ZERO GAS TEST 3) WRONG NAILS IN H.D. AT FRONT DOOR 4) MISSING RETRO REAR SHOWER, EXT. CLIP ITEM WAS NOT SIGNED OFF 5) MISSING SAFETY GLASS FRONT ENTRY 6) STAT WIRE NOT COMPLETED 7) STUD OVERNOTCHED LAUNDRY 8) LOW DWV TEST |