Permit: T06CM02292

Parcel: 141331310


Addresses:

10623 E OTTOMAN DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM02292

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/19/2007 FRAMING Approved IVRS - Inspection :*
01/09/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILING ON SHEAR TRANSFER NOT PER 5/D3
2) SHIM 2 X 12 HEADERS
3) NO ELECTRIC RISER FOR PANEL
4) NO DWV TEST
5) PEX LINES IN KITCHEN, MOVE ABOVE BOTTOM TRUSS CHORD
6) TIGHTEN ALL LOOSE ANCHOR BOLTS
7) MASTER BATH SHOWER NEEDS BLOCKING ON EDGE OF SHOWER
8) NEED TO BLOCK DUCT VENT HALL BATHROOM
9) FIRESTOP CHASE AT HALLWAY BATH