Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02290
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ALL H.D.'S 2) AT GLU LAM GARAGE 10/D6 ADD BLOCKS BETWEEN HIP JACKS, NAIL DECK TO BLKS, INSTALL H2.5 PER DETAIL 3) INSTALL F C-S STRAPS 1ST TO 2ND FLOOR SHEAR 4) NAIL ALL 2ND FLOOR PLATES 5) LIVING ROOM REAR HALF OF FLOOR INSTALL 6'-0" 2 X 4'S 6) NAIL SHEARWALLS BOTTOM PLATES 12" ON CENTER 7) SOME JOINTS ON FLOOR DECK MISSING T & G JOINT BLK FROM BELOW AND NAIL 8) SOME CRIPPLE STUDS TO SHORT SISTER CRIPPLE AT SHORT ONES |