Permit: T06CM02284

Parcel: 141331860


Addresses:

8328 S GUPTA DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02284

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/06/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) AT INTERMEDIATE-NEED ADDITION A.B.'S IN SHEAR AND AT JOINTS
10/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR NAILING INCOMPLETE-CHECK BOTTOM AND TOP PLATES AND JOINTS
2) ANCHOR BOLTS IN SHEAR PANELS NOT PER PLAN
3) INCOMPLETE SHEAR TRANSFER AT INTERIOR SHEARWALLS
4) CABIN TIE ALL APPLICABLE CORNERS OR STRAP
5) STRAP PORCH BEAMS TO POSTS
6) DBL SILL PLATES WITH 5/8" ANCHOR BOLTS REQUIRED ON GARAGE WALL PER DETAIL 10/D5 AND MSTC28 REQUIRED ON HDR
7) GABLE END BRACING REQUIRED PER 2/D2
8) STOPPED INSPECTION-HOUSE NOT READY