Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM02268

Parcel: 123080740


Addresses:

2532 E HELEN ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
09/26/2006 ROOF NAILING Approved IVRS - Inspection :*
08/16/2006 ROOF NAILING Partial Approval IVRS - Inspection :*
08/11/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WORK NOT COMPLETED
2) HOLDOWNS MISSING THROUGHOUT HD1 SWB
3) PER DETAIL 11/S.2 8D COMMONS 6" ON CENTER EDGE 12" FIELD SWA WALLS
4) PROVIDE CONTINOUS TIE DOWN GLUE LAMB FIRST FLOOR
5) DBL STUD UNDER DBL GIRDER BOTH ENDS 2ND FLOOR
6) BLOCKING NOT COMPLETE UPSTAIRS
7) PROVIDE TRUSS CALC'S
8) GAS LINE PER HB 2256 PROVIDE TRACER WIRE
9) STOPPED INSPECTION