Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T06CM02258
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/11/2006 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
12/06/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BATHROOM 4" ALUM. FLEX PIPES -- NOT ALL PIPES IN ROOF FLASHING; ALL MUST BE UP INSIDE OF FLASHING! 2. RE-ADJUST 10" FLEX DUCT, FRONT OF ELEVATOR DOOR, 2ND FLOOR. DUCT IS OVER 40% PINCHED OFF/SHUT. REWORK AS NECESSARY |