Permit: T06CM02202

Parcel: 110083110


Addresses:

2704 N GOYETTE AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/14/2006 FRAMING Approved IVRS - Inspection :*
09/12/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO WATER TEST DWV OR POTABLE WATER
2) SHIM BEARING HEADERS
08/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING FIRE BLOCK GARAGE
2) MISSING NUT GARAGE NORTH WALL AB
3) BLOCK REGISTER BOOTS 3-SIDES
4) TERMINATE EXHAUST FANS TO EXTERIOR
5) NO WATER TEST DWV SYSTEM
6) INSULATE "Y" FITTINGS DUCT WORK
7) SECURE 90 VENT THROUGH ROOF MASTER WATER CLOSET
8) STRAP 2 X 10 ENTRY BEAM DEN AND GARAGE
9) PROVIDE ENGINEER FIX FOR OVERKNOTCH TJI'S GARAGE AT GAS LINE
10) SHIM BEARING HEADERS
11) OVERSPAN HALLWAY CEILING AT DUCTWORK
07/21/2006 FRAMING Not ready for Inspection IVRS - Inspection :*