Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/14/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/12/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WATER TEST DWV OR POTABLE WATER 2) SHIM BEARING HEADERS |
|
| 08/29/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING FIRE BLOCK GARAGE 2) MISSING NUT GARAGE NORTH WALL AB 3) BLOCK REGISTER BOOTS 3-SIDES 4) TERMINATE EXHAUST FANS TO EXTERIOR 5) NO WATER TEST DWV SYSTEM 6) INSULATE "Y" FITTINGS DUCT WORK 7) SECURE 90 VENT THROUGH ROOF MASTER WATER CLOSET 8) STRAP 2 X 10 ENTRY BEAM DEN AND GARAGE 9) PROVIDE ENGINEER FIX FOR OVERKNOTCH TJI'S GARAGE AT GAS LINE 10) SHIM BEARING HEADERS 11) OVERSPAN HALLWAY CEILING AT DUCTWORK |
|
| 07/21/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |