Permit: T06CM02199

Parcel: 110083080


Addresses:

4400 E BERMUDA ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/19/2006 FRAMING Approved IVRS - Inspection :*
09/07/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NOTES 1, 2, 4 AND 9 FROM PREVIOUS
2. MISSING AB GARAGE NE CORNER BRACE PANEL
08/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK BETWEEN HIGH/LOW COMBUSTION VENTS GARAGE
2) NAIL PROTECT ROMEX MIDDLE BEDROOM UNDER WINDOW
3) MASTER BEDROOM SMOKIE WITHIN 36" SUPPLY AIR
4) SHIM BEARING HEADERS
5) STRAP 2 X 8 HEADER ENTRY AT DEN AND GARAGE
6) FIRE BLOCK SOFFIT LAUNDRY
7) DAMAGED FIRE BLOCK LAUNDRY VENT
8) MISSING FIRE BLOCK LAUNDRY
9) GARAGE SERVICE DOOR NOT ON PLANS. REVISE PLAN AS BUILT OR BUILD TO PLAN. EXTERIOR LIGHT WILL BE REQUIRED
07/07/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
WITH INTERMEDIATES