Permit: T06CM02179

Parcel: 13615378B

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/28/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
REVISED APP PLAN ON SITE
02/13/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST THRU BLD TO MANHOLE FOR SITE SEWER OK
02/01/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
BUILDING SEWER REQUIRES CITY APPROVED PLAN CHECK STAMP PER 5/24/07 INSPECTION AND SHALL HAVE MINIMUM FALL PER 2006 UPC
05/07/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
20' FROM SOUTH SIDE OF BUILDING 6" ABS TRACER WIRE AND BUILDING AND TEST OK
04/24/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST UNDERGROUND WASTE & VENT THRU BUILDING WEST OF COLUMN LINE F MY INITIAL P1.08 OK
04/20/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST UNDERGROUND FOR COLUMN LINE C,D,F THRU BUILDING TO MY INITIAL OK
04/09/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) TEST SHALL BE IN PLACE
2) PROVIDE CORRECT FULL SIZE DRAINAGE FITTINGS, MINIMUM ? REQUIRED ON ALL PIPING
3) SHALL INSTALL PER APPROVED PLAN OR PROVIDE RED LINE ON SITE WITH APPROVED PLAN TO BE ON SITE WITH RED LINE AT LATER DATE
4) VENT FITTING BELOW FLOOD RIM OF FIXTURE TO BE OF LONG RADIUS DRAINGER TYPE