Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* REVISED APP PLAN ON SITE |
|
| 02/13/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST THRU BLD TO MANHOLE FOR SITE SEWER OK |
|
| 02/01/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* BUILDING SEWER REQUIRES CITY APPROVED PLAN CHECK STAMP PER 5/24/07 INSPECTION AND SHALL HAVE MINIMUM FALL PER 2006 UPC |
|
| 05/07/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 20' FROM SOUTH SIDE OF BUILDING 6" ABS TRACER WIRE AND BUILDING AND TEST OK |
|
| 04/24/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND WASTE & VENT THRU BUILDING WEST OF COLUMN LINE F MY INITIAL P1.08 OK |
|
| 04/20/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND FOR COLUMN LINE C,D,F THRU BUILDING TO MY INITIAL OK |
|
| 04/09/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) TEST SHALL BE IN PLACE 2) PROVIDE CORRECT FULL SIZE DRAINAGE FITTINGS, MINIMUM ? REQUIRED ON ALL PIPING 3) SHALL INSTALL PER APPROVED PLAN OR PROVIDE RED LINE ON SITE WITH APPROVED PLAN TO BE ON SITE WITH RED LINE AT LATER DATE 4) VENT FITTING BELOW FLOOD RIM OF FIXTURE TO BE OF LONG RADIUS DRAINGER TYPE |