Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM02169

Parcel: 140264650

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02169

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2-NAILS REQUIRED TOP AND BOTTOM AT METAL BRACE
2) NO ROOF ACCESS
3) NAIL STRAPS AROUND CORNER AT FRONT WINDOW
4) SHEAR PANELS MISSING CHECK SHEAR PLAN
5) EXTEND SHEAR TO DBL TOP PLATE