Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T06CM02166
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/01/2006 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
11/21/2006 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT CONNECTED AT UNIT/NO TRACER WIRE |
|
05/26/2006 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* |