Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM02143
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/02/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
04/25/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE PLAN PROVIDE WATER TEST TO 10' PROVIDE 2% SLOPE MIN. IN ALL AREAS REMOVE LARGE CHUNKS FROM SIDE OF DITCH. UNCOVER HCS CONNECTION. COPPER TUBING SHALL BE REAMED TO THE FULL INTERNAL BORE OF THE TUBING. REDO ALL SOLDIER JOINTS THAT ARE NOT REAMED. I WILL CHECK. PEX TUBING SHALL BE UNDER TEST FOR INSPECTION AND SHALL BE SHADE TO 6" ABOVE TUBING W/CLEAN FILL |