Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM02143

Parcel: 140265820

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM02143

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/02/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/25/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE PLAN
PROVIDE WATER TEST TO 10'
PROVIDE 2% SLOPE MIN. IN ALL AREAS
REMOVE LARGE CHUNKS FROM SIDE OF DITCH.
UNCOVER HCS CONNECTION.
COPPER TUBING SHALL BE REAMED TO THE FULL INTERNAL BORE OF THE TUBING.
REDO ALL SOLDIER JOINTS THAT ARE NOT REAMED. I WILL CHECK.
PEX TUBING SHALL BE UNDER TEST FOR INSPECTION AND SHALL BE SHADE TO 6" ABOVE TUBING W/CLEAN FILL