Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02138
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/16/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REINFORCE TOP PLATE WHERE OVERBORED 2) FIRESTOP AT NICHE 3) INSULATE BEHIND TUB SURROUND 4) FIRE STOP AROUND B-VENT 2ND FLOOR 5) FIRESTOP AROUND SUPPLY DUCT IN M. BED CHASE 6) BANG PLATE OVER PLUMBING IN M. BATH 7) BLOCK 3 SIDES OF SUPPLY DUCT IN M. CLOSET 8) FIRESTOP CHASE IN MASTER BATH 9) STOPPED INSPECTION-CANNOT INSPECT AROUND DRYWALL |
|
11/15/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STOPPED INSPECTION TRADES NOT FINISHED 2) FAN UNDER STAIR BATH NOT CONNECTED |