Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM02132
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2006 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 08/10/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/25/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) REAR ADDITION FOOTING OK TO DRY PACK UNDER SLAB |
|
| 05/23/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIVING ROOM BEAM TWISTED AND NEEDS ADDITIONAL SUPPORT UNDERNEATH 2) NEED VERIFICATION OF SOILS CONDITION (SUBSTANDARD) ? 3) MUST MAINTAIN MINIMUM 12" X 12" FOOTING UNDER EXISTING SLAB THROUGHOUT 4) BATHROOM PLATE BOLTS TO MINIMUM 1/2" DIAMETER 48" APART WITHIN 12" ENDS BOTTOM PLATE 5) NEED VERIFICATION OF FOUNDATION REAR ADDITION 6) INSTALL SHIMS BEARING HEADERS AT BEARING AT BEARING POINT GAPS 7) NEED CERTIFIED ENGINEER ANALYSIS OF EXISTING HOUSE FOUNDATION AND MASONRY WALLS AS WELL AS REPAIRS & SPECIAL INSPECTIONS 8) PLYWOOD OVERSPANNED EAST OVER HANG 9) INSTALL H2.5'S & JOIST HANGERS THROUGHOUT 10) INSTALL ADDITION/WIND BRACING SOUTH WALL NEW ADDITION 11) NO ELECTRIC ON PLAN FOR EXISTING STORAGE 12) INSTALL BANG PLATES PLUMBING AND ELECTRICAL THROUGHOUT BOTH SIDES OF STUDS, PLATES, RAFTERS ETC. 13) ELECTRIC S.W. BEDROOM ADDITION NOT PER PLAN 14) INSTALL FIRE BLOCKS ALL FURR DOWNS 15) BEARING HEADERS MISSING TRIMMER STUDS 16) GAS PIPING ROOF NOT SUPPORTED TO MINIMUM CODE REQUIREMENT 17) SECURE POTABLE H20 LINES, H20 HEATER ? ROTATING 18) NEED VERIFICATION OF SOIL PIPE, SEWER, H20 REAR ADDITION 19) PLAN CALLS FOR USING EXISTING DUCT WORK-ALL NEW INSTALLED 20) NEED H20 TEST DWV THROUGH ROOF 21) INSTALL DRYER VENT TO EXTERIOR 22) INSTALL H20 HEATER FLU & COMB/RELIEF VENTS TO EXTERIOR 23) STOPPED INSPECTION: NEED ENGINEER STATEMENT REGARDING SUB-STANDARD FOUNDATION, WALLS, ETC... 24) STOP ALL WORK UNTIL RECTIFIED |
|
| 05/12/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ENGINEERED REPAIR ON SUBSTANDARD FOUNDATION WITH SPECIAL INSPECTION ON SAME 2) NEED TO REPLAC TERMITE DAMAGED WOOD 3) SECURE ROMEX WITH 12" OF BOXES 4) DUCT WORK HANGING OUT OF CEILING 5) NEED TEST DWV PIPING 6) BACK GROUT TUB 7) STOPPED INSPECTION-UNABLE TO LOCATE PLANS |
|
| 05/08/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* |