Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02131
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSE TRUSS FOR INSPECTION |
|
11/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO GAS TEST 2) CLIP INTERIOR BEARING WALL STUDS GARAGE 3) NEED F-10 TRUSS DOCUMENT APPROVED BY CITY |
|
10/19/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) F-10 TRUSS DAMAGED BY PLUMBING. PROVIDE CITY OF TUCSON APPROVED ENGINEER REPAIR 2) NO GAS TEST 3) HORIZONTAL RUN OF W/H VENT MUST RISE 30 DEGREES 4) 1" CLEARANCE REQUIRES W/H B-VENT TO COMBUSTIBLES 5) RED HEAD ANCHORS LOOSE 6) HALL MUST BE 36" FINISHED 7) NO DWV TEST 8) REPAIR DUCT WORK VAPOR BARRIER 9) CAULK LATHE PENETRATIONS 10) STOPPED INSPECTION |