Permit: T06CM02117

Parcel: 141311330

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02117

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/13/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) BLOCK TRUSS BAYS, SKIP EVERY 3RD BAY
2) PARTIAL EXT. CLIP=TWO RETRO-HD'S REQUIRED AT REAR WALL, CHECK AT INTERMEDIATE INSPECTION
07/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied 1) RAT RUNS AT GARAGE DROP CEILING SEE LAST INSPECTION
2) H20 DAMAGED ROOF SHEATHING
3) NO UFER
07/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR BLOCKING PANELS BETWEEN TRUSSES
2) NEED LATERAL BRACING AT 3" 10 5/8" ABOVE DROP GARAGE
3) MISSING TWO P.A.'S AT REAR PATIO
4) SHIM ALL 3 PT BEARING
5) ROOF NAIL CAN'T OK UNTIL SHEAR BLK PANELS AT TRUSSES INSTALLED AND SHEAR NAIL ROOF TO DRAG TRUSSES COMPLETED
06/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING HD'S THROUGHOUT
2) STRAP ? ON DBL TOP PLATE WEST WALL
3) MISSING 4 X 4 POST AT GARAGE HEADER
4) NO TRUSS CALC'S ON SITE
5) SHEAR ON ROOF NOT NAILED
06/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*