Permit: T06CM02114

Parcel: 141311380

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM02114

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/28/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING RAT RUNS THROUGH OUT
2) LOOSE WIND BRACE
3) NAIL SHEAR PANELS ROOF TO PANEL USE 10D SO THEY CAN BE SEEN FROM BELOW