Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM02100
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEDGERS MISSING A35'S 2) TWO NAILS TOP AND BOTTOM WIND BRACING 3) NEED APPROVED TRUSS DRAWINGS 4) CST STRAP MISSING FRONT AT 2ND FLOOR SPLIT 5) SHEAR TRANSFER PLATE NAILING NOT PER SCHEDULE OR TOP PLATE 6) INSTALL BANG PLATES BOTTOM PLATES AT PLUMBING CUTS 7) STOPPED INSPECTION |