Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM02092
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/23/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
11/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT 3.1 3B.5, 3A, 2F 2.75-2.10, 1H 1-1 2.4 24 H - 2-F 16'8" |
|
11/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTHSIDE OF WEST END TO 14 FOOT OK TO GROUT |
|
11/09/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* YOU MUST HAVE ALL STEEL, AND TRAPS IN PLACE. YOU ALSO NEED TO HAVE SCAFFOLD READY YOU MAY GROUT ON VETERANS DAY WITH APPROVAL OF SPECIAL INSPECTOR. |
|
11/07/2006 | REINFORCED MASONRY PRE-GROUT | Cancelled | CANCELLED PER CONTRACTOR GREG #480-421-8674 | |
11/07/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CANCELLED BY CONTRACTOR |
|
11/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' WINDOWS TOP EAST END DO NOT GROUT WITHOUT APPROVAL OF BUILDING INSPECTOR TOP OUT ON STAIRWELL AND ELEVATOR SHAFT. |
|
11/02/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LINE I-H, TOP 2.4-2.7/2-? 20' ELEVATOR AND STAIR EXTEND 2ND SET 18" DOWN PAST SILL TO TOP OF WALL |
|
10/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4TH LIFT ELEVATOR SHAFT 3RD SOUTH WALL |
|
10/30/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT ELEVATOR OK, 8' LIFT AT WINDOWS SOUTH EAST CORNER. |
|
10/27/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* JOB SITE LOCKED COULD NOT ACCESS @ 1530 HOURS PLEASE RECALL |
|
10/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' LIFT ELEVATOR, TOP OUT EAST WALL |
|
10/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' LIFT EXTERIOR WALLS, EAST, WEST AND NORTH WALLS |
|
10/20/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' ELEVATOR CORE; 12' WEST REAR PERIMETER |
|
10/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8' PERIMETER OF BLD. OK |
|
10/04/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE INFORMATION ABOUT INSPECTION REQUESTED PROVIDE APPROVED PLANS AND INSP. RECORD CARD. |
|
10/03/2006 | REINFORCED MASONRY PRE-GROUT | Cancelled | IVRS - RI canceled | |
09/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT NORTH, EAST & WEST WALL 1ST LIFT SOUTH WALLS |
|
09/27/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* SITE LOCKED 3:39 PM |
|
09/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 4' WEST WALL AND NORTH WALL EXCEPT FOR COLUMN POP-OUTS | |
09/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR STEM OK |
|
09/18/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXCAVATION ON INTERIOR FOOTING OK |
|
09/15/2006 | REINFORCED MASONRY PRE-GROUT | Cancelled | CANCELLED PER SUB-CONTRACTOR DAVID #488-9121 VIA PHONE CONVERSATION AT 11:36 AM ON 9/15/06 | |
09/15/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* RECALL OR PROVIDE RFI |
|
09/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM WALL CLOCKWISE FROM 2.10/2.6 TO 3A/31 |