Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T06CM02091
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/29/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MAKE ALL CONNECTIONS HOOK UP ALL APPLIANCES DON'T FORGET HAMMER ARRESTORS |
|
09/25/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. INSULATE EXPOSED WATER LINE ON EXTERIOR WALL 2. OK TO COVER P.O.C TO EXISTING SEWER, WATER TEST OK 3. SEAL EXTERIOR WALL PENETRATIONS 4. SCREW VENT CAP FOR W.H 5. REMOVE TAPE AT DBL. WALL 6. INSTALL SHUT OFF AT HOT WATER INLET TO WH 7. AUTOMATIC WASHER STAND PIPE RECEPTOR TO BE ROUGHED IN BETWEEN 6"-18" AFF. STAND PIPE TO BE 18"-30" 8. GAS PRESSURE TEST OK |
|
09/24/2008 | PLUMBING - FINAL | Not ready for Inspection | ||
09/23/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
09/22/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |