Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM02062
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 08/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAIRS SHALL HAVE 7 3/4" MAX HEIGHT AND NOT EXCEED THE SMALLEST BY 3/8" 2) SEAL EXTERIOR SIDEING WITH SILACONE CAULK AT BASE 3) SEAL PLUG HOLES/OPENING IN ELECTRICAL 4) PROVIDE WEATHER TIGHT FITTING AT ELECTRIC CONDUIT 5) ADDITION ON EACH SIDE OF EXISTING MOBILE HOME HAS BLOCKED REQUIRED CROSS VENTILATION 6) PROVIDE VENTILATION AS REQUIRED 7) SECURE GAS LINE 4'-0" ON CENTER MAX 8) ELECTRIC WIRE BINDING ON LIGHT FRAME 9) SECURE FLOURESCENT LIGHT BULB ENDS |
|
| 08/21/2006 | BUILDING - FINAL | Cancelled | CANCELLED PER CONTRACTOR GLENN #665-1829 | |
| 08/21/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NO READY PER OWNER |
|
| 08/16/2006 | BUILDING - FINAL | Denied | MEANS OF HEAT FOR GAME ROOM STOOP AT WEST DOOR REMOVE PLUMBING AT LAUNDRY AND CHANGE PLAN RECEPTACLE AT WORKSHOP EAST WALL SOUTH RECEPTACLE DOES NOT OPERATE LIGHTS AT GAME ROOM ARE FLUSH MOUNT TYPE SLOPE FTG AWAY FROM BLDG CIRCUIT BREAKERS FOR NEW ADDITION ? |
|
| 08/15/2006 | BUILDING - FINAL | Not ready for Inspection | SPOKE TO HECTOR LOPEZ/I ASKED HIM IF HE WOULD DO THE INSPECTION FOR DNR-AND WHEN THEIR REQUIREMENTS WERE SATISFIED WE WOULD DO OUR INSPECTION. HE IS TO NOTIFY OWNER | |
| 08/10/2006 | BUILDING - FINAL | Denied | 1) SEE WATER UP FOR 8/3/06 ABOVE 2) OWNER SAID BEDROOM S/B WORKSHOP 3) HEATING AND COOLING NOT ADDRESSED 4) VENTALATION UNDER MH NOT ADDRESSED |
|
| 08/03/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLANS APPROVED ARE MISLEADING THE SUPPOSE EXISTS DWELLING IS A MOBILE HOME BETWEEN 2 ADDITIONS MUST SUBMIT A COMPLETE SET OF DRAWINGS IDENTIFYING, ALL STRUCTURAL, ELEC, MECH. & PLBG. SITUATIONS. |
|
| 08/02/2006 | BUILDING - FINAL | Not ready for Inspection | MISSING BLANK COVERS @ L/B'S BOX & I.D CIRCUITS STOPPED INSPECTION. |
|
| 07/28/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VERIFY PROGRESS |