Permit: T06CM02061

Parcel: 112081020


Addresses:

2916 E CANNES ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM02061

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/11/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/07/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PREVIOUS CORRECTIONS TO BE COMPLETED (ALL) BEFORE YOU RECALL
2. PROVIDE LADDER TO ROOF

REFEE IF NOT ALL CORRECT NEXT INSPECTION
09/05/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. IDENTIFY AC DISCONNECTS
2. SECURE SERVICE RECEPTACLE TO PEDESTAL
3. GAS PIPE NOT RUN IN FRONT OF DISCONNECT
4. MULTI-WIRE BRANCH CKT'S TO TERMINATE ON SEPARATE PHASES
5. GFI OR SINGLE RECEPT. GAR
6. INSTALL BOX EXTENDERS AS NEEDED
7. NEED ARC FAULT PROTECTION ALL 120V BEDROOM OUTLETS LIGHTS, SMOKES RECEPTACLES
8. PANEL DIRECTORIES TO BE NEAT, LEGIBLE AND CORRECT.