Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/05/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWIST EQUIPMENT GROUNDS, THEN CRIMP 2) IDENTIFY WHITE USED AS HOT 3) NEED NAIL PLATES 4) SMOKE DETECTORS MIN, 36" FROM HVAC VENT 5) HAVE OVER FILLED WASHER BOX 6) LOOSE CAN LIGHT UPSTAIRS CEILING |
|
| 01/02/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER COMMON WALLS |
|