Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T06CM02060
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PLAN CALLS FOR A FLOOR DRAIN INSTALLED IS A BELL REDUCER SEE NOTES FROM 08 2007 |
|
08/28/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* IT HAS BEEN AGREED THAT DUE TO THE METHANE BARRIER REQUIREMENTS, AN FHA FLOOR DRAIN AND TRAP PRIMER IS IMPRACTICAL. A HUB DRAIN WITH STRAINER WILL BE ACCEPTED ON THIS JOBSITE. |
|
08/20/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) DRAIN IN MECHANICAL ROOM NOT ON THE PLAN 2) A FITTING IS NOT AN APPROVED INDIRECT WASTE RECEPTACLE 3) INDIRECT WASTE PIPING NOT PER PLAN |
|
08/17/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* TEST REQUIRED AFTER CONCEALMENT OF GAS PIPING REMOVE TRAP ON SOFTENER DRAIN LABEL ELECTRICAL PANEL WATER HAMMER ARRESTORS REQUIRED AT WASHER BOX WATER HEATER NOT PER DETAIL 203 |