Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM02060
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* NOTE: DISPOSAL SWITCH BOX OVERFILLED BY ONE CONDUCTOR. |
|
03/05/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EQUIPMENT GROUNDS TO BE TWISTED TOGETHER-THEN CRIMPED 2) LAUNDRY RECEPTACLE HANGING 3) IDENTIFY WHITE USED AS HOT 4) KITCHEN 2 GANG OVER FILLED ? 5) NEED NAIL PLATES-KITCHEN SWITCH-OTHER AREAS 6) TIGHTEN GAS BOND |
|
03/02/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/02/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER COMMON WALLS |
|
12/28/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION FOR COMMON WALL ONLY 1) NAIL NOT ALLOWED IN BOXES-NEC 314.23 B1 2) NAIL PLATE AS NEEDED-NEC 300.4 |