Permit: T06CM02048

Parcel: 136328070

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/27/2007 FRAMING Approved IVRS - Inspection :*
03/26/2007 FRAMING Partial Approval IVRS - Inspection :*
03/22/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK AT DRYER VENT
2) BLOCK REGISTER IN LAUNDRY
3) IF BREAKFAST BAR OVERHANGS OVER 6", REMOVE RECEPTS
4) SECURE RECEPTACLE FURNACE ROOM
5) SMOKIES TO BE 6"-12" BELOW CEILING
6) LIGHT AND SKY LIGHT MASTER CLOSET ?
7) ADD RECEPTACLE DINING ROOM AND HALL BATH
8) NO PRESSURE ON TEST ON INSIDE GAUGE
9) B-VENT MUST HAVE MINIMUM 30 DEGREE PITCH FURNACE CLOSET
10) PEX MUST BE MINIMUM 12" FROM CAN LIGHTS
11) EXTEND CLEANOUT MASTER BATH THRU WALL