Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM02025
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
09/29/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ENGINEERED TRUSS REPAIR REQUIRED FOR FLOOR TRUSS IN DINING AND LIVING ROOM AREA 2) STRAP GLU LAM TO POSTS SAME AREAS AND 4-2 X 4'S REQUIRED UNDER GLU LAM NAILED TIGHT 3) SECURE/STAPLE ELECTRIC WIRES BY REAR WINDOW IN LIVING ROOM 4) 10 POUND MINIMUM TEST REQUIRED 5) BLOCK AIR VENT 2ND FLOOR BATH 3 SIDES |
|
09/20/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL STUCCO MESH AT KITCHEN HOOD VENT 2) ANTI-SIPHON ON ALL HOSE BIBS 3) 60 DEGREE MAX OFF SET FOR WATER HTR B-VENT 4) NO GAS PRESSURE 5) FIREBLOCK SOFFIT AT STAIRWAY 6) PEX 12" FROM CAN LIGHTS OVER KITCHEN 7) INSUFFICIENT SLOPE ON 3" DRAIN OVER ENTRY 8) FIRESTOP STAIRWELL/CHASE 9) FIRESTOP KITCHEN SOFFIT 10) COMPLETE WIREING TO CAN LIGHT OVER KITCHEN 11) STOPPED INSPECTION |