Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01987

Parcel: 11507239A


Addresses:

323 W LEE ST


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T06CM01987

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/15/2010 BUILDING - FINAL Approved IVRS - Inspection :*
12/14/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) COMPLY WITH PREVIOUS
2) NO ONE HOME
3) REFEE WILL APPLY NEXT DENIAL
12/06/2010 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) NOTES 11 & 12 FROM PREVIOUS
2) GAS CARD OK
12/02/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) RECALL ONLY AFTER LIST OF 12 ITEMS IS COMPLETE
2) IF YOU CALL AGAIN BEFORE IT IS COMPLETE, THERE WILL BE A REFEE CHARGE
11/30/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ITEMS 1-9 FROM PREVIOUS
11/10/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS
2) LOWER CLEANOUTS FOR GRADE
3) VACUUM BREAKER HOSE BIBBS
4) COMPLETE B-VENT INSTALLATION WATER HEATER
5) PROTECT ROMEX UNDER 8' MECH. ROOM
6) SEAL WATER CLOSERTS AT BASE
7) COMPLETE BATH EXHAUST FANS
8) ALL WINDOW SECURITY BARS MUST OPERATE FREELY WITHOUT SEPERATE TOOLS FOR EMERGENCY EGRESS
9) PAINT ROOF VENTS ABS
10) PROVIDE SAFE ACCESS TO ROOF TOP
11) BLANK DEAD FRONT UNUSED OPENINGS
12) PROVIDE CERTS