Permit: T06CM01982

Parcel: 134162420

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/16/2006 FRAMING Approved IVRS - Inspection :*
11/14/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
11/09/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL VACUUM BREAKERS
2) FIREBLOCK SOUTH POP OUT IN GARAGE
3) CUT BACKING 1" AWAY FROM B-VENT IN GARAGE
4) FIRE STOP KITCHEN CHASE UNDER STAIRS
5) REPAIR INSULATION ON LINE SET OVER LOFT