Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T06CM01979

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/13/2007 PLUMBING - YARD WTR LINE/TEST Approved
08/17/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
08/17/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
2" PVC - 2" CU CONNECTION AT 2" RP IS OK
1 1/2" CONNECTION NOT VISIBLE
INSTALLATION NOT PER PLAN
07/20/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1. OK TO COVER OVERHEAD
2. NEED TO SEE METER AND RPPBP CONNECTIONS
3. GREASE TRAP INSTALLED OK
06/20/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
AT HAND SINK IN KITCHEN - TRAP ARM MAY NOT CHANGE SIZE TRAP AND TRAP ARM TO BE THE SAME SIZE
TRAP MAY BE ONLY ONE SIZE LARGER THAN CONNECTIVE TAILPIECE. OK TO COVER ALL OTHER AREAS.
06/12/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
06/01/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
05/22/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
YARDWATER NOT INSTALLED PER PLAN
2" PVC W/TRACER INSTALLED FROM NEW RPPBP LOCATION
TO COPPER BLDG. SERVICE OK SUBJECT TO REDLINE.
01/08/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
SITE SEWER TIED INTO EXISTING SEWER OK
APPROX 40' INSTALLED WITH TEST OK
OK TO COVER THIS SECTION ONLY INSTALLED PER REDLINE
YARDWATER NOT READY