Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01970
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAT RUN DOESN'T REACH LAST TRUSS 2) TWISTED 2 X 4 CAUSES-INSUFFICIENT CONNECTION |
|
| 08/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled | |
| 07/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAT RUN A-1 TRUSSES 2) USE 16D NAILS IN ALL P.A.'S 3) 3 PT BEARING SHIM THROUGHOUT 4) USE 10D'S AT ALL SHEAR BLOCKING PANELS SO THEY CAN BE SEEN FROM BELOW 5) USE DBL H2.5 AT EACH GIRDER 6) MARKED IN BLK, MISSING NAILS |