Permit: T06CM01962

Parcel: 136154780


Addresses:

8070 E SENATE ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01962

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/25/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADD SHEAR S.W. CORNER
2) CLEAN UP BELLY BAND OVER GARAGE DOOR
3) NAIL BELLY BAND INTO BEAM BY STAIRS
4) STRAP BEAM AT STAIRS TO POST
5) T-11D TRUSS TWISTED-22 1/2 SPACING ONE PLACE AND 27" SPACING ELSEWHERE
6) RENAIL ROOF WHERE MARKED ON FLOOR