Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01955
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/14/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) REPAIR CONCRETE ORDERED-SLURY MIX AND POURED 2/13/07. NOW READY FOR NEXT LIFT-CALL FOR FINAL INSPECTION WHEN JOB IS COMPLETE |
|
| 01/30/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAIRS NEED TO BE FIXED 2) NEED TO POUR CONCRETE IN ? UNDER STAIRS |
|
| 01/25/2007 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Leak in DWV test toilet above garage Post tension slab cut and cable damaged 2' x 2' hole powder room. Provide City approved engineer repair by address Do not place concrete until inspected by City inspector Slab ? you must provide soil compaction certified by third party inspector Block duct boots in loft Stair rise exceeds 7 3/4" and 3/8" difference Stairs at windersm less than 36" wide Stopped inspection |
|
| 01/23/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H.D. IN DINING ROOM HAS NO NAILS 2) ITEM 34 HAS NOT BEEN CORRECTED 3) CHASE AT LAUNDRY ROOM NEED FIRESTOP 4) NO DWV TEST |
|
| 01/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP CHASES AS NECESSARY 2) FIRESTOP PENETRATIONS IN TOP PLATES AND TUBS 3) ADD RED HEAD WINDOW NEAR FRONT DOOR 4) BLOCK TRANSFER DUCT LOFT 5) ADD SMOKIE WEST BEDROOM HALLWAY 6) USE FHA STRAPS 2" ABS N. WALL GARAGE 7) NO DWV WATER TEST 8) SUPPLY OK 9) RAISE LINE SETS TO PROVIDE 30" VERTICAL CLEARANCE AT PLATFORM |