Permit: T06CM01955

Parcel: 141331750


Addresses:

8393 S GUPTA DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01955

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/20/2007 FRAMING Approved IVRS - Inspection :*
02/14/2007 FRAMING Partial Approval IVRS - Inspection :*
1) REPAIR CONCRETE ORDERED-SLURY MIX AND POURED 2/13/07. NOW READY FOR NEXT LIFT-CALL FOR FINAL INSPECTION WHEN JOB IS COMPLETE
01/30/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STAIRS NEED TO BE FIXED
2) NEED TO POUR CONCRETE IN ? UNDER STAIRS
01/25/2007 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Leak in DWV test toilet above garage
Post tension slab cut and cable damaged 2' x 2' hole powder room. Provide City approved engineer repair by address
Do not place concrete until inspected by City inspector
Slab ? you must provide soil compaction certified by third party inspector
Block duct boots in loft
Stair rise exceeds 7 3/4" and 3/8" difference
Stairs at windersm less than 36" wide
Stopped inspection
01/23/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H.D. IN DINING ROOM HAS NO NAILS
2) ITEM 34 HAS NOT BEEN CORRECTED
3) CHASE AT LAUNDRY ROOM NEED FIRESTOP
4) NO DWV TEST
01/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRESTOP CHASES AS NECESSARY
2) FIRESTOP PENETRATIONS IN TOP PLATES AND TUBS
3) ADD RED HEAD WINDOW NEAR FRONT DOOR
4) BLOCK TRANSFER DUCT LOFT
5) ADD SMOKIE WEST BEDROOM HALLWAY
6) USE FHA STRAPS 2" ABS N. WALL GARAGE
7) NO DWV WATER TEST
8) SUPPLY OK
9) RAISE LINE SETS TO PROVIDE 30" VERTICAL CLEARANCE AT PLATFORM