Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01954
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/19/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) AT FRAME CHECK KITCHEN H/D FOR PROPER BOLTS |
|
09/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN ON SHEARWALL NORTH SIDE DINING ROOM NOT NAILED TO SHEARWALL 2) ANCHOR BOLTS SHEARWALL HOLDOWN NOT TIGHTENED (KITCHEN) 3) KITCHEN WALL TOP PLATE SHOUD BE DBL 2 X 6 CLIPPED AND NAILED 4) VARIOUS CLIPS THROUGHOUT MISSING NAILS AND CLIPS |