Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01945
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO COVER ROOF AND WALLS 2) CHECK SHEAR BEHIND LEDGER AT GLU LAM |
|
08/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) COMPLETE SHEAR TO GLU LAM |
|
08/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FRONT SHEAR 2ND FLOOR (3) RUN OSB DOWN TO GARAGE BEAM 2) ADD LTP4'S AT (3) SHEAR BOTH SIDES OF 2ND FLOOR |
|
08/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NAIL OFF FRONT SHEAR WALL 3" + 12" ON CENTER 2) ADD WIND BRACE 2ND FLOOR EAST WALL |
|
08/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NAIL OFF FRONT SHEAR WALL 3" + 12" ON CENTER 2) ADD CS HEAD OF STAIRS AT SHEARWALL 3) ADD WIND BRACE EAST END OF NORTH WALL ON 1ST FLOOR 4) ADD WIND BRACE 2ND FLOOR EAST WALL |