Permit: T06CM01942

Parcel: 141331800


Addresses:

8370 S GUPTA DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01942

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/25/2006 FRAMING Approved IVRS - Inspection :*
10/23/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO TIGHTEN HOLDOWN HTT16 GARAGE TO HOUSE
2) SHEARWALL BOTTOM PLATE 2ND FLOOR STAIRWAY NOT NAILED
3) BROKEN EXHAUST FAN DUCT-GARAGE
4) SHEARWALL OFF SET 2ND FLOOR BAY WINDOW NEES MORE NAILS BOTTOM PLATE
10/19/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS NEEDED IN BOTTOM PL. SHEAR AT STAIR 10 D 4" ON CENTER
2) WALL OFF SET 2ND FLOOR WEST ?
3) MISSING HTT16 GARAGE TO HOUSE WALL AT DOOR
4) SHIM LET INS
5) BROKEN EXHAUST FAN, DUCT AND GARAGE
6) REWORK H20 FLUE