Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM01940
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2006 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
05/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) MAIN ADDITION AND STORAGE OK TO POUR 2) PORCH AND CARPORT NOT READY |
|
05/23/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLAN CALLS FOR 18" WIDE FOOTINGS 2) SOIL PIPE NOT TO RUN UNDER FOOTINGS PARALLEL 3) UNCOVER ALL PIPING 4) INSTALL GLUED FITTINGS SEWER LINE 5) PLASTIC GAS LINE REQUIRES 18" DEPTH OF COVER 6) INSTALL BLUE TRACER WIRE H20 LINE & GREEN TRACER WIRE SEWER LINE 7) CARPORT AND PORCH FOOTINGS IN COMPLETE 8) STOPPED INSPECTION |