Permit: T06CM01940

Parcel: 117080300


Addresses:

821 S 3RD AV


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T06CM01940

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
06/05/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/26/2006 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) MAIN ADDITION AND STORAGE OK TO POUR
2) PORCH AND CARPORT NOT READY
05/23/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLAN CALLS FOR 18" WIDE FOOTINGS
2) SOIL PIPE NOT TO RUN UNDER FOOTINGS PARALLEL
3) UNCOVER ALL PIPING
4) INSTALL GLUED FITTINGS SEWER LINE
5) PLASTIC GAS LINE REQUIRES 18" DEPTH OF COVER
6) INSTALL BLUE TRACER WIRE H20 LINE & GREEN TRACER WIRE SEWER LINE
7) CARPORT AND PORCH FOOTINGS IN COMPLETE
8) STOPPED INSPECTION