Inspection History Details
Permit: T06CM01938
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/07/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK |
|
| 06/18/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ADDRESSING PROBLEM NO UNIT #14 AT 2900 N. SWAN |
|
| 06/16/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - WATER PIPING OK TO COVER. - DWV W/TEST THRU ROOF OK TO COVER WALLS. - PROVIDE SUPPORT ON OVERHEAD ABS. - CLOSET FLANGE NOT YET INSTALLED. - CALL FOR CLOSET FLANGE INSPECTION, FLANGE SHALL BE INSTALLED SO THAT TOP OF FLANGE IS 1/4" ABOVE FF AND SHALL BE SECURED TO FLOOR. |