Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01928
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* NEED RETRO FOR H.D ON SOUTH WALL WILL CHECK AT INTERMEDIATE. |
|
11/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM #3, 4, 6, 9 AND 11 NOT CONNECTED 2) NO ACCESS |
|
11/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLIP CORNERS AT POP-OUT OVER GARAGE 2) RSP4 CLIPS MISSING VARIOUS PLACES 3) FAA STRAPS BOTTOM PLATE NORTH EXTERIOR WALL 4) CLIP AND STRAP BAY WINDOW 5) NEED TWO A35 PATIO JOIST 6) H.D. SOUTHWEST CORNER MISSING SHEARWALL 7) H2.5 GLU LAM GARAGE 8) FIRST FLOOR SHEAR AT GARAGE MISSING SIMPSON HTT-16 9) PARALLEL TRUSS BLOCKING 2/D6 MISSING 10) DBL GIRDER MISSING DBL STUD 2ND FLOOR N.W. CORNER AND H.25 11) GABLE END TRUSS BLOCK NOT PER PLAN 12) EDGE BLOCKING NOT NAILED WITH 8D |