Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SW8 NOT NAILED 4-12 SPACING
2) SW8 ANCHOR BOLT SPACING MAX 24" ON CENTER
3) SHEARWALL NAILS SET TOO DEEP
4) SW7 ANCHOR BOLT SPACING MAX 32" ON CENTER
5) C.S. 18 STRAPS MISSING FRONT SHEAR ABOVE GARAGE
6) INSTALL MTT 28B INTERIOR SHEARWALLS
7) NEED TRUSS DRAWINGS
8) NEED LADDER
9) STOPPED INSPECTION
06/14/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PRE-SLAB APPROVAL