Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01901

Parcel: 140263960

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM01901

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2006 FRAMING Approved IVRS - Inspection :*
10/11/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1" CLEARANCE FROM COMBUSTIBLE REQUIRED AT B-VENT, WATER HEATER AND FURNACE
10/09/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADD STUD UNDER TRUSS BY REF. LINE 1ST FLOOR
2) 2ND FLOOR GIRDER SHALL BE TRANSFERED CONTINOUS TO 1ST FLOOR
3) SECURE WATER LINE AT S.O.V.
4) LEAK AT WASTE LINE 2ND FLOOR
5) 1" CLEARANCE FROM COMBUSTIBLE REQUIRED AT B-VENT AT WATER HEATER AND FURNACE
6) EXTEND DRYER VENT TO T-CAP
7) REDO/REPLACE OVER NOTCHED STUDS AT INTERIOR BEARING/SHEARWALL