Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 09/28/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - #8 CONDENSATE PIPE RUNNING UPHILL, ALUM. FLEX COMING LOOSE @ TAPED JOINT - #6 O.S.A FALLED FROM ROOF JACK, MECHANICALLY FASTEN R/A BLOCKING CEILING ACCESS - #4 E.F PARTIALLY IN WALL - #1 NO ATTIC ACCESS, RE-DO CONDENSATE PIPE FROM 90 TO UNIT, USE PRIMER - #'S 2, 3, 5, 7 MECHANICAL OK TO ROCK |
|
| 09/21/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED ACCESS TO ATTIC UNITS NEED SCREWS IN E.F DUCTING CONN. TO FAN REPLACE BROKE FLEX @ U.STAIRS BATH E.F CONNECT CONDENSATE PER MANUF. INSTRUCTS. PLATE STRAPS CUTTING INTO REF. LINES CHECK ALL UNITS FOR CORRECTIONS BACK DRAFT DAMPERS NOT WORKING ON DRYER VENTS |