| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/25/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* PLUMBING FINAL OK |
|
| 03/17/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. HAVE APPROVED PLAN ON SITE 2. PROVIDE SIGNAGE IN ELECTRICAL PANELS NON-BONDED PLASTIC WATER PIPING 3. PROVIDE WATER HAMMER ARRESTORS AT HOT & COLD SUPPLY TO WASHING MACHINES 4. PROVIDE CLAMP FOR HIGH LOOP ON DISHWASHER DRAIN HOSE LIST MAY NOT BE COMPLETE |