Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/10/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - FURNCO NOT LISTED FOR USE INSIDE BUILDING - USE A MISSION COUPLING FOR PL TO PL OR USE AN ABS COUPLING. |
|
| 06/29/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - HANGER MISSING ON CSST OVERHEAD - MISSION COUPLING AT DRAIN REPAIR IS LISTED FOR USE ON CAST IRON. - COUPLING SHALL BE LISTED FOR PLASTIC TO PLASTIC - HAVE HOSE READY FOR RUN TEST - POOL FILL & SHOWER NOT CORRECTED |
|
| 06/25/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 5140, 5240, 5241, 5141, 5236, 5136 - OK 5237 - N/R 5137 - N/R DW HOSES SHALL BE SECURED 2" FROM COUNTERTOP 5235, 5238, 5138, 5139, 5238 - T&P BLOCKAGE & LEAK WC SEWER SMELL - HB VAC BREAKERS - SERVICE HANDLES - PAINT EXPOSED PLASTIC VENTS - MAKE T&P TERMINATIONS CLEAR, USE ROCKS WHERE NECESSARY - INSP. STOPPED |
|
| 06/21/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REPAIR DAMAGED DRAIN PIPE AND PIPE CONDENSATE TO APPROVED RECEPTOR. 2. INSTALL TEMPERATURE LIMITING VALVE FOR PUBLIC USE LAVATORIES. 3. COMPLETE SHOWER 4. MAKE POOL FILL VALVES OPERATIONAL, ATMOSPHERIC VACUUM BREAKERS CAN HAVE NO VALVES DOWNSTREAM 5. GAS PRESSURE TEST IS OK. COMPLETE PIPE SUPPORTS. |
|
| 02/13/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |