Permit: T06CM01875

Parcel: 13314460A

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/03/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/29/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1. KITCHEN COUNTER TO HAVE 2 CIRCUITS 210.52 (5244)
2. CORRECTLY GROUND PANELS (5244, 5343, 5344)
06/27/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
#5239, #5238, #5237, #5236
NEED APPROVED GROUND BAR

OK 11 UNITS EXCEPT AS NOTED
OK ROOF
06/25/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. GROUND JUNCTION BOXES & FILL UNUSED OPENINGS
2. GROUNDING EQUIPMENT CONDUCTOR TO BE 3/4 OF A TURN UNDER SCREW
3. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED AN APPROVED EXTENDER RING.