| 02/16/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/14/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - USE PRIMER ON PVC DRAINS OK TO WATER TEST PVC ALREADY INSTALLED - SUPPORT ALL PLASTIC DRAINS AT NOT MORE THAN 4'. - CORRECT SLOPE ON DRAINS. - TEST TUBS TO OVERFLOW LEVEL. |
|
| 02/12/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. #4125 PROVIDE TEST ON TUB AND UNDERGROUND WET SOIL AND WET UNDER SHOWER. 2. 4225 OK 3. 4126 - ABS PIPE LEAKING IN MASTER BATH COPPER PIPING PROVIDE 10 MIL TAPE AT BANG PLATES 4. 4127 - NOT READY FOR INSPECTION 5. 4128 - NOT READY 6. 4226 - REPAIR LEAK ON WATER PIPING IN MASTER BATH 7. 4227 - REPAIR LEAK AT WASHER BOX 8. 4228 - PROVIDE TEST ON TUB LIST NOT COMPLETE |