Permit: T06CM01872

Parcel: 133170630


Addresses:

350 N WILMOT RD


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T06CM01872

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/12/2008 BUILDING - FINAL Approved
04/11/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
OK TCO FOR PATIENTS

- TAKE VERY CLOSE LOOK AT ALL ACCESSIBLE RESTROOMS
- JUSTIFY WHY ANY MULTI-USER RESTROOMS ARE NOT ACCESSIBLE.
- PROVIDE DIRECTIONAL SIGNAGE TO NEAREST ACCESSIBLE TOILET, FOUNTAIN, ETC. IF FULL ACCESSIBILITY IS NOT MET.
04/09/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
MUST HAVE 1, 2, 3 BY FRIDAY

1. VERTICAL GRAB BARS REQUIRED ALL ACCESSIBLE RESTROOMS @ W.C
2. SWEEPS @ ALL DOORS IN STAIRWELLS TO BE PROPERLY ADJUSTED
3. SMOKE SEALS @ ALL DOORS TO BE ADJUSTED
4. RESTROOMS IN LOBBIES NEED TO HAVE ACCESSBILE RESTROOM SIGNAGE & VERTICAL GRAB BAR
5. I STILL NEED TO TALKE TO PLUMBING, MECH. AND ELEC. INSPECTORS
6. QUICK DISCONNECT & SIGN WILL BE OK @ SOAP
DISPENSER @ MOP SINKS (NO VALVES DOWN STREAM)
04/03/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1. GUARD RAMP @ SE REQUIRES THAT YOU MAY
NOT PASS A 4" SHEER
2. PAINT OUT CROSSINGS
3. REVISE SITE PLAN (ENGINEER MAY CALL ME) FOR INDICATED LOADING ZONES & TRUNC. DOMES & CROSSINGS
4. MOVE EXIT SIGN 1ST FLOOR ELEVATOR LOBBY
5. GRAB BARS 5TH FLOOR/ACCESSIBLE SIGNAGE 5TH FLOOR
6. 5TH FLOOR EXIT SIGN @ N.W STAIR TO BE DIRECTIONAL
7. EXIT SIGNS IN AREA AROUND STAIR B ARE CONFUSING (REMOVE 4 REPLACE 1)
8. PLEASE ARRANGE MEETING WITH ARCHITECT TO GO FLOOR BY FLOOR WITH BLDG. INSP. FOR EXIT SIGNS
9. PROVIDE SEALS & SWEEPS ON ALL FIRE AND SMOKE DOORS OR GIVE ME A CODE SECTION THAT EXEMPTS YOUR INSTALLATION CHECK NFPA80
03/21/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
TCO FOR STAFFING TO BE APPROVED WITH ELECTRICAL PARTIAL SATURDAY 3/22

1. VERTICAL GRAB BARS @ ACCESSIBLE RESTROOMS
2. 4TH FLOOR MAKE FIRE PILLOWS SMOKE TIGHT
3. 5TH FLOOR MAKE FIRE PILLOWS SMOKE TIGHT
03/20/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
FOR TCO STAFF ONLY
A. MAKE SURE ALL ADA ROOMS CORRECTLY IDENTIFIED WITH CORRECT HARDWARE

1. SEALS & SWEEPS ON ALL RATED DOORS ON 2HR WALLS AND STAIRWELLS AND SMOKE DOORS IN CORRIDORS (DOOR TO SMALL ROOMS OK)
2. PLEASE PROVIDE CABLE TRAY ROUTE AND REMOVE TILE ON BOTH SIDES OF SEPARATION DOORS
3. POST SIGNS "NOT AN EXIT" WHERE REQUIRED
PROVIDE EMERGENCY EXIT ROUTE PLANS TO ANY STAFF
4. THRESHOLD IN BACK STAIR - ALL DOORS AND DOOR HARDWARE IN CORRIDORS
03/07/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
ALL PROGRESS LOOKS GOOD
TCO FOR STAFFING REQUIRES
1. FIRE ALARMS GOOD
2. FIRE SPRINKLER GOOD
3. GRAB BARS @ STAIRS
4. FINAL FIRESTOP @ DATA TRAYS
02/28/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
YOUR SINKS ARE TOO HIGH
YOUR TOILETS ARE TO FAR FROM WALLS
01/30/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
5 COLUMN POURS @ EAST CANOPY OK
01/11/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
5 EACH F7 FOOTINGS
FOR CANOPY OK