Permit: T06CM01872

Parcel: 133170630


Addresses:

350 N WILMOT RD

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
04/03/2008 BUILDING - PROGRESS Approved IVRS - Inspection :*
03/14/2008 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED NEEDS TO MEET W/LEE RAY
02/14/2008 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
KEEP ALL LEVEL 2 SIGNS SO THEY CAN BE SEEN BY MEN ON KNEES - YOUR CURRENT PLAN IS OK
11/16/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
11/16/2007 BUILDING - PROGRESS Partial Approval BRICK VENEER TIES OK
NEED VAPOR FIX
10/05/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
ALL LATH 100% OK
09/19/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
1) ALL EXTERIOR ? GLASS OK
2) OK ALL STUCCO MESH OK
09/12/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
LATH ATRIUM & MOST OF HIGH HAT
08/24/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
1. DENS GLASS ON SOUTH & WEST UP TO PARAPET
2. LATH EAST SIDE & 2ND FLOOR SOUTHSIDE
08/16/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
LATH @ N. END AREA B
08/09/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
LATH AREA OK
08/06/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
S.E STAIRWELL -- REINFORCING STEEL & SLABS ON FLOORS 4-5-6 OK TO POUR
07/16/2007 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
AREA TOO WET TO EPOXY
07/13/2007 BUILDING - PROGRESS Cancelled
07/03/2007 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
07/02/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS ROOF DECKING ON AREA B
GIRD K-X/1-15, MUST PROVIDE INSPECTION FOR PARAPET FRAMING PRIOR TO COVER
06/25/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS BASEMENT STAIRS AND NORTH END OF BASEMENT STAIRS TOP LANDING (TUNNEL)
06/14/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
1) THIS INSPECTION COVER "DOG HOUSE" SHEATHING/ROOF/WALL SPECIFIC DETAIAL BY RFI
05/16/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS THE FOLLOWING AREA BY GIRDLINES P.O-T.O/1.8-7.0 EQUIP. AND
ELEVATOR N.5-P.4/1.5-2.0
FOR REINFORCING ON CONCRETE SLAB ON GRADE
SPECIAL INSPECTION REPORT FOR HIGH ST. BOLTS PROVIDED K-W/1.5 AREA B
05/15/2007 BUILDING - PROGRESS Cancelled
05/11/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
1) NOTE: THIS INSPECTION COVER LEVEL AREA A WELDING SPECIAL INSPECTION REPORT PROVIDED GIRD LINE 1.7-3.9/.5A-4.7
05/10/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS THE FOLLOWING AREA
LEVEL 1
AREA B
GIRDLINE R-N.1/1.2-2.5
SPECIAL INSPECTION REPORT PROVIDED.
04/12/2007 BUILDING - PROGRESS Partial Approval GRIDLINE 15/K-5 REINFORCING FOR CURB, SPECIFIC DETAIL 16 WITH 2 #5 @ 12" O.C CONT. PLUS #4 CONT. HORZ. REINF.
ON SHEET S6.4
04/09/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
04/05/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
5TH FLOOR AREA B
GRIDLINE 1-7/P.4-X, 7-13/T-X, 13-14/P-X, 14-15/P-W.3
PROVIDED REPORTS FOR WELDING OK
AND REINFORCED STEEL ON SLAB
NEED PROVIDE REPORT FOR HIGH STR. BOLTS FOR 5TH FLOOR AREA B
04/04/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
DETAIL 2, ON SHEET S4.4 CURD ON FOURTH FLOOR
03/21/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
NOTE: 4TH FLOOR PART B
GRIDLINE P-X/1.0-15.0
REPORT FOR CONCRETE REINFORCING ON FOURTH FLOOR PART B
03/16/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
3RD FLOOR, OK TO POUR, PART B REPORTS FOR HIGH STR. BOLTS AND WELDING PROVIDED PLUS REINFORCING STEEL ON DECK (REPORT PROVIDED)
03/12/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
AREA SECOND FLOOR (B-2) GRID P-X/14-15
PROVIDED WELDING REPORTS AND HIGH STR. BOLTS
REINFORCING STEEL ON DECK
03/09/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
MUST PROVIDE SPECIAL INSPECTIONS REPORTS FOR SECOND FLOOR B.2
03/05/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
FIFTH FLOOR AREA "B-1"
GRIDLINE K-Q/1-15 SQ.
PROVIDE HIGH STR. BOLTS & WELD REPORTS
OK PROVIDED SPECIAL INSP. REPORT FOR REINFORCED REBAR ON CONC. SLAB
03/02/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
FIFTH FLOOR AREA "B-1"
GRIDLINE K-Q/1-15 SQ. OK TO POUR
PROVIDED HIGH STR. BOLTS & WELD REPORTS
02/23/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
4TH FLOOR K-P/1-15 OK TO PLACE SLAB
01/18/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*